Brand Name: Yutong
Model Number: YY(Q)W
Place of Origin: Henan, China (Mainland)
Condition: New
Type: Natural Circulation
Usage: Industrial
Structure: Fire Tube
Pressure: Low Pressure
Style: Horizontal
Fuel: light oil/heavy oil /gas fired
Output: Heat
Dimension(L*W*H): 5500mm*2400mm*3000mm
Weight: 14.5t
Certification: ISO9001:2000 | ISO9001:2008 | QS-9000 | SGS BV
After-sales Service Provided: Engineers available to service machinery overseas
Rated thermal power: 2900KW/2500000Kcal
thermal efficiency: 85%
design pressure: 0.9Mpa
working pressure: 0.6Mpa
Highest working temperature: 320°C
furnace oil capacity: 2.4m3
pipe connecting diameter: 150mm
thermal capacity: 100,000Kcal-5000,000Kca for customer choose
charater: high temperature,low pressure
burner: world famous brand
Fuel oil /gas fired heat exchanger boiler
Introduction:
1. This series boiler takes heat carrier oil as medium and uses the hot oil circulating pump force the medium to make Liquid circulation; then the thermal energy will be transmitted to the devices and back to the furnace to be reheated.
2. So the boiler can get higher working temperature at low pressure, and make a better usage of heat, it is a kind of safe boiler with high efficiency and low power consumption.
3. The fuel (oil, gas) light a fire by burner to produce flame and flame goes into the internal coil to form radiation heating surface.
4. Then it through rear coil tube forward rotated 180 ° into the tubes and to circulate into second interlayer, finally it will enter the atmosphere.
Features:
1. It is convenient to be adjusted, and can supply balanced heat to satisfy the hard work required to precise temperature.
2. Liquid circulation heating, less heat loss, high thermal efficiency.
3. Working medium can change volume when it was heated and release heat .and we have compensation technique measures in the system.
4. We have strictly technical measures to control air, water and other low volatile matter’s content of the working medium in the circulation heating
5. The series boiler have advanced program control system, equipped with liquid level controller, pressure controller, temperature controller, and alarms to make sure the boiler work orderly and safe. So it is a kind of safe boiler with high efficiency and low power consumption.
Technical parameters
Model | YY(Q)W-120YC | YY(Q)W-230YC | YY(Q)W-350YC | YY(Q)W-470YC | YY(Q)W-700YC | YY(Q)W-930YC | YY(Q)W-1200YC | YY(Q)W-1400YC | YY(Q)W-1800YC | YY(Q)W-2300YC | YY(Q)W-2900YC | YY(Q)W-3500YC | YY(Q)W-4100YC | YY(Q)W-4700YC | YY(Q)W-5800YC |
rated power | 120 | 230 | 350 | 470 | 700 | 930 | 1200 | 1400 | 1800 | 2300 | 2900 | 3500 | 4100 | 4700 | 5800 |
thermal efficiency | 75 | 80 | 85 | 85 | 85 | 85 | 85 | 85 | 85 | 85 | 85 | 85 | 85 | 85 | 85 |
Design pressure(Mpa) | 0.9 | 0.9 | 0.9 | 0.9 | 0.9 | 0.9 | 0.9 | 0.9 | 0.9 | 0.9 | 0.9 | 0.9 | 0.9 | 0.9 | 0.9 |
work pressure(Mpa) | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 |
Highest working temperature | 320 | 320 | 320 | 320 | 320 | 320 | 320 | 320 | 320 | 320 | 320 | 320 | 320 | 320 | 320 |
Furnace capacity( m3 ) | 0.1 | 0.2 | 0.28 | 0.38 | 0.55 | 0.75 | 1 | 1.3 | 1.6 | 2 | 2.4 | 3 | 3.2 | 3.7 | 4.5 |
Oil circulation( m3 ) | 12.5 | 32 | 40 | 60 | 80 | 100 | 100 | 100 | 160 | 160 | 200 | 200 | 200 | 260 | 300 |
tubing diameter(mm) | 50 | 65 | 80 | 80 | 100 | 125 | 125 | 125 | 125 | 150 | 150 | 150 | 200 | 200 | 250 |
Diameter*width*height(m) | 1.5*1.115*1.4 | 2.0*2.5*1.5 | 2.5*1.35*1.65 | 2.7*1.6*1.9 | 3.1*1.65*1.95 | 3.5*1.7*2.0 | 3.85*1.8*2.16 | 4.35*1.9*2.27 | 4.8*2.0*2.5 | 5.3*2.2*2.75 | 5.5*2.4*3.0 | 5.8*2.5*3.1 | 6.3*2.8*3.3 | 6.5*3.0*3.5 | 7.0*3.1*3.6 |
reference weight | 2 | 2.9 | 3.7 | 4.5 | 4.9 | 5.5 | 6.5 | 7.5 | 9.8 | 12.3 | 14.5 | 21.5 | 25.5 | 29.5 | 37.5 |
Boiler in workshop
Vistors
Certificate
If you have any enquires about our products , please feel free to contact us, we will try our best to satisfy you, thank you for supporting, please contact via with